General Features

  • Mechanical Characteristic of the foam at Overall Density of 40(+/-2) kg/ m3
  • Tensile Strength : 150 ~ 250 kpa
    Compression Strength : 100 ~ 210 kpa
    Shear Strength : 100 ~ 240 kpa
    Fire property : B3 as per DIN 4102 (B2 & PIR upon request)
  • Insulation Capacity
  • K value (Thermal conductivity of PU) : 0.020 W/mK
    Tolerance : +/- 0.002

    Polyrethane Core Thickness (mm) T = 30 T = 35 T = 40 T = 50 T = 60 T = 80 T = 100
    Overall Heat Transfer
    Coefficient 'U' Value
    W/M2 °C 0.630 0.540 0.475 0.380 0.316 0.237 0.190
  • Water absorption of the foam
  • After 24 hours : 1.0% of Volume
    Closed Cells : 93%
    Advisable Length : 2.5 meters – 6 meters
    Standard width : 1150mm & 1180 mm (However can be customized)
*The Standard width depends on Quantity & Availability.